{"id":333,"date":"2022-12-06T08:44:21","date_gmt":"2022-12-06T08:44:21","guid":{"rendered":"https:\/\/takao.boiler.co.jp\/en\/?post_type=product&#038;p=333"},"modified":"2023-03-20T23:04:23","modified_gmt":"2023-03-20T14:04:23","slug":"sft","status":"publish","type":"product","link":"https:\/\/takao.boiler.co.jp\/en\/product\/sft\/","title":{"rendered":"SFT Boilers"},"content":{"rendered":"\n<div class=\"swell-block-columns\"><div class=\"swell-block-columns__inner\">\n<div class=\"swell-block-column swl-has-mb--s\" style=\"--clmn-w--tab:50%;--clmn-w--pc:60%\">\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"391\" height=\"425\" src=\"https:\/\/takao.boiler.co.jp\/en\/wp-content\/uploads\/2022\/12\/pi-sft-boiler.jpg\" alt=\"SFT Boilers\" class=\"wp-image-1431\" srcset=\"https:\/\/takao.boiler.co.jp\/en\/wp-content\/uploads\/2022\/12\/pi-sft-boiler.jpg 391w, https:\/\/takao.boiler.co.jp\/en\/wp-content\/uploads\/2022\/12\/pi-sft-boiler-276x300.jpg 276w\" sizes=\"(max-width: 391px) 100vw, 391px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"swell-block-column swl-has-mb--s\" style=\"--clmn-w--tab:50%;--clmn-w--pc:40%\">\n<h2 class=\"is-style-default has-huge-font-size wp-block-heading\">Features<\/h2>\n\n\n\n<ul class=\"-list-under-dashed product-feature-list wp-block-list\">\n<li>High Performance<\/li>\n\n\n\n<li>Energy Saving Structure<\/li>\n\n\n\n<li>Quick Start Up<\/li>\n\n\n\n<li>Tough and Long Service Life<\/li>\n\n\n\n<li>Space Saving<\/li>\n<\/ul>\n<\/div>\n<\/div><\/div>\n\n\n\n<h3 class=\"is-style-default u-mb-ctrl u-mb-0 wp-block-heading\">\u25a0 GAS<\/h3>\n\n\n\n<figure class=\"wp-block-image size-full is-resized sp_only\"><img decoding=\"async\" src=\"https:\/\/takao.boiler.co.jp\/en\/wp-content\/uploads\/2022\/12\/scroll-en.gif\" alt=\"scrollable\" class=\"wp-image-2024\" width=\"250\" height=\"15\"\/><\/figure>\n\n\n\n<figure class=\"wp-block-flexible-table-block-table is-scroll-on-pc is-scroll-on-mobile boiler-table bt3\"><table class=\"has-fixed-layout is-sticky-first-column\"><thead><tr><th style=\"color:#333333;background-color:#f7fbe6\">Boiler Type No.<\/th><th style=\"color:#333333;text-align:center\">SFT-1000G<\/th><th style=\"color:#333333;text-align:center\">SFT-1300G<\/th><th style=\"color:#333333;text-align:center\">SFT-1500G<\/th><th style=\"color:#333333;text-align:center\">SFT-1800G<\/th><th style=\"color:#333333;text-align:center\">SFT-2000G<\/th><\/tr><\/thead><tbody><tr><th style=\"background-color:#f7fbe6\">Rated Output<br>Equivalent Evaporation [kg\/h]<\/th><td style=\"text-align:center\">1000<\/td><td style=\"text-align:center\">1300<\/td><td style=\"text-align:center\">1500<\/td><td style=\"text-align:center\">1800<\/td><td style=\"text-align:center\">2000<\/td><\/tr><tr><th style=\"background-color:#f7fbe6\">Rated Output<br><strong>Heat Quantity [kW]<\/strong><\/th><td style=\"text-align:center\">626<\/td><td style=\"text-align:center\">815<\/td><td style=\"text-align:center\">940<\/td><td style=\"text-align:center\">1128<\/td><td style=\"text-align:center\">1253<\/td><\/tr><tr><th style=\"background-color:#f7fbe6\"><strong>Fuel Consumption [m\u00b3N\/h]<\/strong><\/th><td style=\"text-align:center\">60.4<\/td><td style=\"text-align:center\">78.6<\/td><td style=\"text-align:center\">90.6<\/td><td style=\"text-align:center\">108.8<\/td><td style=\"text-align:center\">120.9<\/td><\/tr><tr><th style=\"background-color:#f7fbe6\">Heating Suface Area [m\u00b2]<\/th><td colspan=\"5\" style=\"text-align:center\">9.4<\/td><\/tr><tr><th style=\"background-color:#f7fbe6\"><strong>Boider Estimated Weight [ton]<\/strong><\/th><td colspan=\"5\" style=\"text-align:center\">3.4<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"u-mb-ctrl u-mb-0 wp-block-heading\">Notes<\/h4>\n\n\n\n<ol class=\"wp-block-list\">\n<li>The fuel consumption of city gas is based on the low heating value (40.6 MJ\/m\u00b3N).<\/li>\n\n\n\n<li class=\"u-mb-ctrl u-mb-40\">It is necessary to decide the height of the stack based on the surrounding situation and regulations.<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator has-text-color has-alpha-channel-opacity has-background is-style-wide\" style=\"background-color:#cccccc;color:#cccccc\"\/>\n\n\n\n<h3 class=\"is-style-default u-mb-ctrl u-mb-0 wp-block-heading\">\u25a0 OIL<\/h3>\n\n\n\n<figure class=\"wp-block-image size-full is-resized sp_only\"><img decoding=\"async\" src=\"https:\/\/takao.boiler.co.jp\/en\/wp-content\/uploads\/2022\/12\/scroll-en.gif\" alt=\"scrollable\" class=\"wp-image-2024\" width=\"250\" height=\"15\"\/><\/figure>\n\n\n\n<figure class=\"wp-block-flexible-table-block-table is-scroll-on-pc is-scroll-on-mobile boiler-table bt3\"><table class=\"has-fixed-layout is-sticky-first-column\"><thead><tr><th style=\"color:#333333;background-color:#f7fbe6\">Boiler Type No.<\/th><th style=\"color:#333333;text-align:center\">SFT-1000<\/th><th style=\"color:#333333;text-align:center\">SFT-1300<\/th><th style=\"color:#333333;text-align:center\">SFT-1500<\/th><th style=\"color:#333333;text-align:center\">SFT-1800<\/th><th style=\"color:#333333;text-align:center\">SFT-2000<\/th><\/tr><\/thead><tbody><tr><th style=\"background-color:#f7fbe6\">Rated Output<br>Equivalent Evaporation [kg\/h]<\/th><td style=\"text-align:center\">1000<\/td><td style=\"text-align:center\">1300<\/td><td style=\"text-align:center\">1500<\/td><td style=\"text-align:center\">1800<\/td><td style=\"text-align:center\">2000<\/td><\/tr><tr><th style=\"background-color:#f7fbe6\">Rated Output<br><strong>Heat Quantity [kW]<\/strong><\/th><td style=\"text-align:center\">626<\/td><td style=\"text-align:center\">815<\/td><td style=\"text-align:center\">940<\/td><td style=\"text-align:center\">1128<\/td><td style=\"text-align:center\">1253<\/td><\/tr><tr><th style=\"background-color:#f7fbe6\"><strong>Fuel Consumption [kg\/h]<\/strong><br>non economizer<\/th><td style=\"text-align:center\">61.3<\/td><td style=\"text-align:center\">79.6<\/td><td style=\"text-align:center\">91.9<\/td><td style=\"text-align:center\">110.3<\/td><td style=\"text-align:center\">\u2015<\/td><\/tr><tr><td style=\"background-color:#f7fbe6\"><strong>Fuel Consumption [kg\/h]<br>with economizer&nbsp;<\/strong><\/td><td style=\"text-align:center\">58.6<\/td><td style=\"text-align:center\">76.2<\/td><td style=\"text-align:center\">87.9<\/td><td style=\"text-align:center\">105.5<\/td><td style=\"text-align:center\">\u3000117.2<\/td><\/tr><tr><th style=\"background-color:#f7fbe6\"><strong>Heating Suface Area [m\u00b2]<\/strong><\/th><td colspan=\"5\" style=\"text-align:center\">8.6<\/td><\/tr><tr><th style=\"background-color:#f7fbe6\"><strong>Boiler Estimated Weight [ton]<\/strong><\/th><td colspan=\"5\" style=\"text-align:center\">3.4<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h4 class=\"u-mb-ctrl u-mb-0 wp-block-heading\">Notes<\/h4>\n\n\n\n<ol class=\"wp-block-list\">\n<li>The fuel consumption of oil is based on the low heating value (41.87 MJ\/kg).<\/li>\n\n\n\n<li>It is necessary to decide the height of the stack based on the surrounding situation and regulations.<\/li>\n<\/ol>\n","protected":false},"excerpt":{"rendered":"<p>\u25a0 GAS Notes \u25a0 OIL Notes<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","template":"","format":"standard","meta":{"_editorskit_title_hidden":false,"_editorskit_reading_time":0,"_editorskit_is_block_options_detached":false,"_editorskit_block_options_position":"{}","swell_btn_cv_data":"","footnotes":""},"class_list":["post-333","product","type-product","status-publish","format-standard","hentry"],"_links":{"self":[{"href":"https:\/\/takao.boiler.co.jp\/en\/wp-json\/wp\/v2\/product\/333","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/takao.boiler.co.jp\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/takao.boiler.co.jp\/en\/wp-json\/wp\/v2\/types\/product"}],"author":[{"embeddable":true,"href":"https:\/\/takao.boiler.co.jp\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/takao.boiler.co.jp\/en\/wp-json\/wp\/v2\/comments?post=333"}],"version-history":[{"count":24,"href":"https:\/\/takao.boiler.co.jp\/en\/wp-json\/wp\/v2\/product\/333\/revisions"}],"predecessor-version":[{"id":2233,"href":"https:\/\/takao.boiler.co.jp\/en\/wp-json\/wp\/v2\/product\/333\/revisions\/2233"}],"wp:attachment":[{"href":"https:\/\/takao.boiler.co.jp\/en\/wp-json\/wp\/v2\/media?parent=333"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}